The Electricity Regulatory Authority has made several amendments to the Electricity Service Provision Manual through seven approved mechanisms, with the aim of improving services, handling complaints regarding retroactive electricity bill corrections in a professional manner, and increasing consumer satisfaction and fairness various grievance cases.
Bill Review and Meter Replacement
The amendments require the service provider to review the bill—after verifying its accuracy and comparing it with previous bills—to provide the consumer with the review results and request payment. If the consumer is not convinced and wishes to have the meter inspected, they must pay the inspection fee; if the electricity meter is found to be defective, the inspection fee is refunded to the consumer, and the meter is replaced at the service provider’s expense if it cannot be calibrated, If the meter is found to be in good working order, the consumer is required to pay the bill, and the inspection fee is not refunded. The service provider must notify the consumer of their right to file a complaint with the Authority.
One of the most notable amendments is the revision of paragraph (33-2) to read as follows: The service provider must inspect and calibrate meters free of charge, according to specific schedules for all types of installed meters.
Meter Inspection in Case of Errors in Electricity Bills
Article (40) is also amended to read as follows: If an audit of consumption bills or a meter inspection reveals an error in the calculation of actual consumption, the situation shall be handled as follows: Meter inaccuracy: If the inspection reveals that the meter is inaccurate (the accuracy margin exceeds the permissible limit specified in the appendix), the service provider must rectify the situation by calibrating the meter or replacing it with a similar, functional meter immediately, in accordance with specified formulas.
If the service provider discovers that the multiplication factor used to calculate consumption is incorrect, the service provider must immediately inspect the meter to verify the correctness of the multiplication factor and recalculate the consumer’s bills based on the correct multiplication factor.
Repairing Malfunctions and Correcting Billing Period Errors
If a technical malfunction is confirmed in the meter, whether total or partial, or if an error is found in the meter’s connections—regardless of whether the error occurred at the time of installation or thereafter— for a reason not attributable to the consumer, the service provider shall immediately repair the malfunction or replace the meter with a similar, functional meter at its own expense, and the bill shall be corrected retroactively, applying the tiered rate system when calculating consumption if the tariff is tiered.
The correction shall cover the entire period of the error, and the full amount of the differences shall be refunded in cash to the consumer; if there were multiple consumers during the period of the error, each shall be refunded their respective share of these differences. The correction applies for a period not exceeding six months for residential consumption and for a period not exceeding one calendar year for all other consumption categories, The actual consumer is billed for the differences, which are to be paid in installments not exceeding 10 % per month.
Regulations Governing Payment for Corrections
Among the regulations governing payment for corrections and adjustments is that the service provider is entitled to payment for corrections and adjustments in the following cases: If the service provider fails to comply with inspection and calibration procedures or fails to provide proof of meter inspection and calibration, or if the service provider fails to repair or replace the meter within a period not exceeding 30 days.
Accumulation of Amounts Owed by the Consumer
Article (41) has been amended to read as follows: If an error is discovered in the meter reading or if financial amounts accumulate against the consumer for any reason—such as failure to issue bills or the service provider’s negligence in collecting dues—these cases shall be handled in accordance with the provisions of the manual.
Failure to Prove Violations
Paragraph (42-3) has also been amended to read as follows: “If the service provider fails to complete all procedures for recording and substantiating the violation, in accordance with the provisions of the Regulations for the Protection of Service Providers” Facilities, this shall be considered a failure on the part of the service provider and shall not be subject to correction.“
Complaints Prior to Disconnection of Electric Service
And paragraph (43-1) is amended to read as follows: ”If a complaint is filed before the electricity service is disconnected, the service provider shall not disconnect the electricity service even if the deadline specified in the notice has passed, and the service provider must review the bill and verify its accuracy and consistency with previous consumption records."